4073

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Compile cycle functions define machine data number %1 several times

%1 = Machine data number

Can only occur when installing compile cycle functions. Two different compile cycle applications use the same machine data number. The machine data which was defined twice is shifted into the free number range above 64000.

- Alarm display.

The error has no effect on the usability of the machine data and the function of the compile cycle application. To ensure that the compile cycle machine data documentation is correct, you must contact the supplier of the compile cycle. Only the supplier can remedy the error by changing the software.

Switch control OFF - ON.


1-83


© Siemens AG 2005 All Rights Reserved