4050
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
NC code identifier %1 cannot be reconfigured to %2
%1 = String: Old identifier %2 = String: New identifier
Renaming of an NC code was not possible for one of the following reasons:
The old identifier does not exist
The new identifier is within another type range.
NC codes/keywords can be reconfigured as long as you stay within the type range.
Type 1: "true" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: addresses which can be set: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Correct machine data 10712: NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified Following odd address: New identifier e.g.: NC_USER_CODE_CONF_NAME_TAB [10] = "ROT",
NC_USER_CODE_CONF_NAME_TAB [11] = " " clears the ROT function from the control Switch control OFF - ON.
1-76