4040

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 axis identifier %2 not consistent with machine data %3

%1 = Channel number %2 = String: Axis identifier %3 = String: MD identifier

%4 = There are not enough channel axes entered in the MD displayed.

The use of the specified axis identifier in the displayed MD is not consistent the channel's axis configuration stated in the MD 20070 AXCONF_MACHAX_USED and MD 20050 AXCONF_GEOAX_ASSIGN_TAB.

Only with active "OEM transformation" compile cycle: There are not enough channel axes entered in the MD displayed.

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check and correct the identifier used in the MDs 10000 AXCONF_MACHAX_NAME_TAB, 20080 AXCONF_CHANAX_NAME_TAB and/or 20050 AXCONF_GEOAX_NAME_TAB.

Only with active "OEM transformation" compile cycle: In addition to the specified MD, check and correct MD 24110 TRAFO_AXES_IN_1[n] of the activated OEM transformation according to the function description.

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved