4036

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Wrong NCU link configuration by MD %1

%1 = String: MD identifier

Occurs only with an NCU link system. Different interpolation and position control cycles have been set in the NCUs of the LINK group. This is only allowed if the function FAST-IPO-LINK in MD $MN_MM_NCU_LINK_MASK has been activated.

Caution: For diagnostic purposes, two additional alarm parameters are output together with this alarm.

1.2nd parameter: Position control or IPO cycle time of this NCU 2. 2nd parameter: Position control or IPO cycle time of another NCU.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Activate FAST-IPO-LINK function in MN_MM_NCU_LINK_MASK Or do not set different position control or IPO cycles on the NCUs (see MN_IPO_SYSCLOCK_TIME_RATIO and MN_POSCTRL_SYSCLOCK_TIME_RATIO). Switch control OFF - ON.