4019

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis container %1 advance not allowed with current status of NCU %2

%1 = NCU number

%2 = Axis container number

This error only occurs with direct advancing of the container. With direct container advancing, only one channel is allowed to activate the NC language command for advancing the container. In order to ensure this, the other channels must have the reset status and the axes must be stationary.

With NCU link, the above condition applies to all channels of the NCU group.

Error parameters:

1 : NC Ready missing

16: At least one other channel is active

35: AXCT axis is active following axis/spindle

36: AXCT axis is active leading axis

39: Axis/spindle disable active

40: Overlaid motion active for AXCT axis

41: Axis replacement active for AXCT axis

42: Interpolator active for one axis container axis

46: Rotating spindle with different Ipo cycle of NCUs

47: New-Config active

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

The program must be canceled with Reset and the zero offset deselected before activating the axis container switch.

Clear alarm with the RESET key. Restart part program


© Siemens AG 2005 All Rights Reserved


1-56