4011

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 invalid identifier used in machine data %2[%3]

%1 = Channel number %2 = String: MD identifier %3 = Index: MD array

When defining names in the channel-specific tables for geometry axes and channel axes, one of the following syntax rules for the identifier to be entered has been violated:

The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numerical extension (840D: 1-99, FM-NC: 1-9).

The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for system variable).

The identifier must not be a keyword of the NC language (e.g. POSA).

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Enter the identifier for user-

defined names with correct syntax in the displayed MD

Geometry axes: 20060 AXCONF_GEOAX_NAME_TAB

Channel axes: 10000 AXCONF_MACHAX_NAME_TAB

Switch control OFF - ON.


1-49


© Siemens AG 2005 All Rights Reserved