Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 invalid identifier used in machine data %2[%3]
%1 = Channel number %2 = String: MD identifier %3 = Index: MD array
When defining names in the channel-specific tables for geometry axes and channel axes, one of the following syntax rules for the identifier to be entered has been violated:
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numerical extension (840D: 1-99, FM-NC: 1-9).
The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for system variable).
The identifier must not be a keyword of the NC language (e.g. POSA).
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD
Geometry axes: 20060 AXCONF_GEOAX_NAME_TAB
Channel axes: 10000 AXCONF_MACHAX_NAME_TAB
Switch control OFF - ON.
© Siemens AG 2005 All Rights Reserved