4010 |
Invalid identifier used in machine data %1[%2] |
Parameters: |
%1 = String: MD identifier %2 = Index: MD array |
Definitions: |
When determining a name in the NCK tables (arrays) for: machine axes, Euler angles, Richtungsvektoren, direction vectors, interpolation parameters and intermediate point coordinates, one of the following syntax rules for the identifier to be entered has been violated: |
Reactions: |
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numerical extension (840D: 1-99, FM-NC: 1-9) The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for system variable). The identifier must not be a keyword of the NC language (e.g. POSA). - NC not ready. - Mode group not ready, also effective for single axes - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Please inform the authorized personnel/service department. Enter the identifier for user-defined names with correct syntax in the displayed MD. Machine axes: AXCONF_MACHAX_NAME_TAB Euler angles: EULER_ANGLE_NAME_TAB Normal vectors: NORMAL_VECTOR_NAME_TAB Direction vectors: 10640 DIR_VECTOR_NAME_TAB |
Program Continuation: |
Interpolation parameters: 10650 IPO_PARAM_NAME_TAB Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB Switch control OFF - ON. |
© Siemens AG 2005 All Rights Reserved
1-48