4010

Invalid identifier used in machine data %1[%2]

Parameters:

%1 = String: MD identifier %2 = Index: MD array

Definitions:

When determining a name in the NCK tables (arrays) for: machine axes, Euler angles, Richtungsvektoren, direction vectors, interpolation parameters and intermediate point coordinates, one of the following syntax rules for the identifier to be entered has been violated:

Reactions:

The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numerical extension (840D: 1-99, FM-NC: 1-9)

The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for system variable).

The identifier must not be a keyword of the NC language (e.g. POSA).

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Enter the identifier for user-defined names with correct syntax in the displayed MD.

Machine axes: AXCONF_MACHAX_NAME_TAB

Euler angles: EULER_ANGLE_NAME_TAB

Normal vectors: NORMAL_VECTOR_NAME_TAB

Direction vectors: 10640 DIR_VECTOR_NAME_TAB

Program Continuation:

Interpolation parameters: 10650 IPO_PARAM_NAME_TAB

Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved

1-48