4002

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 machine data %2[%3] assigns an axis not defined in channel

%1 = Channel number %2 = String: MD identifier %3 = Index: MD array

Only axes that have been activated in the channel by means of the channel-specific machine data 20070 AXCONF_MACHAX_USED [kx]=m may be declared as geometry axes or transformation axes by means of the MD 20050 AXCONF_GEOAX_ASSIGN_TAB [gx]=k. This also applies to

$MC_FGROUP_DEFAULT_AXES (gx: Geometry axis index, kx: Channel axis index, k: Channel axis no., m: Machine axis no.).

Assignment of geometry axes to channel axes AXCONF_GEOAX_ASSIGN_TAB (includes channel axis no. k):

Geometry axis index: 0,    1.    0,    2nd channel:    1,2. 0, 2nd    channel: 1

Geometry axis index: 1,    1.    0,    2nd channel:    2, 2. 0, 2nd    channel: 0

Geometry axis index: 2,    1.    0,    2nd channel:    3, 2. 0, 2nd    channel: 3

AXCONF_MACHAX_USED (includes machine axis no. m):

Channel axis    index: 0,    1.    0, 2nd    channel:    1,    2.    0,    2nd channel:    4

Channel axis    index: 1,    1.    0, 2nd    channel:    2,    2.    0,    2nd channel:    5

Channel axis    index: 2,    1.    0, 2nd    channel:    3,    2.    0,    2nd channel:    6

Channel axis    index: 3,    1.    0, 2nd    channel:    7,    2.    0,    2nd channel:    0

Channel axis    index: 4,    1.    0, 2nd    channel:    8,    2.    0,    2nd channel:    0

Channel axis    index: 5,    1.    0, 2nd    channel:    0,    2.    0,    2nd channel:    0

Channel axis    index: 6,    1.    0, 2nd    channel:    0,    2.    0,    2nd channel:    0

Channel axis    index: 7,    1.    0, 2nd    channel:    0,    2.    0,    2nd channel:    0

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department.

Check and correct either

$MC_GEOAX_ASSIGN_TAB

$MC_TRAFO_AXES_IN_X

$MC_TRAFO_GEOAX_ASSIGN_TAB_X

$MC_FGROUP_DEFAULT_AXES

and/or $MC_AXCONF_MACHAX_USED.

Switch control OFF - ON.


1-43


© Siemens AG 2005 All Rights Reserved