2102

NCK battery alarm

Definitions:

The undervoltage monitoring (2.4 - 2.6 V) of the NCK battery was detected during system power-up.

Reactions:

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Pull out the battery/fan unit from the NC module and replace the battery (type: lithium battery with lead, size 1/2 AA, 850 mAh, min. 3.2 V).

The system must then be reinitialized because it must be assumed that data has been lost in the buffered RAM during the last power-off phase as a result of insufficient supply voltage (refer to Section 2.2 in the Installation and Start-up Guide for the procedure).

The following data might have been corrupted or entirely lost:

NC machine data

Drive machine data

Option data

Setting data

User variable

Global subroutines

Cycles and macros, as well as

PLC machine data

PLC basic program

PLC user program, and all

PLC user data

Program Continuation:

User data in the NCK and PLC (e.g. tool and workpiece data) that have been altered by the manufacturing process since the last data backup must be updated manually to match the present machine status!

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved

1-26