Heidenhain iTNC 530 HSCI motor monitorig functions

In case of alarms the 8B30motor temperature is too high, 8BB0 motor temperature low, etc. you can temporarily disable the alarms in parameter 2220.Temperature too low -bit 5.too low -bit 4

Physically check that the temperature is OK before making changes.(the problem is with temperature sensor)This is only a temporary solution (motor, cable, module need to be repaired).

You can also block other faults here. Bit 7 input frequency encoder ( 8860 Input frequency of speed encoder %.2s , 8C60 Signal frequency at encoder of speed input %.2s etc.)

MP2220 Monitoring functions
;Input: %xxxxxxxxxxxxxxxx
;Bit 0 Reference-mark monitoring
; 0 = Active
; 1 = Not active
;Bit 1 Monitoring of rotational direction
; 0 = Active
; 1 = Not active
;Bit 2 Power limiting of the spindle for -ERR.IZ.GR
; (only for HEIDENHAIN inverters except UE 2xx)
; 0 = Active
; 1 = Not active
;Bit 3 Vibrations are suppressed during switch-off of
; drive
; 0 = Active
; 1 = Not active
;Bit 4 only CC 424, CC 61xx:
; Monitoring temperature too high
; 0 = Active
; 1 = Not active
;Bit 5 only CC 424, CC 61xx:
; Monitoring temperature too low
; 0 = Active
; 1 = Not active
;Bit 6 reserved
;Bit 7 CC 422: reserved
;Bit 7 only CC 424, CC 61xx:
; Monitoring input frequency encoder
; 0 = Active
; 1 = Not active
;Bit 8 only CC 424, CC 61xx:
; Compensating the mechanical offset
; by a step by step increasing of the kV
; 0 = Active
; 1 = Not active